Differences

This shows you the differences between two versions of the page.

Link to this comparison view

Both sides previous revision Previous revision
Last revision Both sides next revision
503_error_production_terminal [2019/01/29 10:43]
kcifreo
503_error_production_terminal [2019/01/30 09:21]
127.0.0.1 external edit
Line 1: Line 1:
-======   ======+======  ======
  
-**Cause:** 
  
-Production Terminal not restarting service after reboot due to a Windows update.+ 
 +====**Cause:** Production Terminal not restarting service after reboot due to a Windows update.==== 
  
 **Event Viewer Log:** **Event Viewer Log:**
 +
 +
  
 //Administrative events reflected warning:A process serving application pool 'pt' exceeded time limits during shut down. The process id was '284'.// //Administrative events reflected warning:A process serving application pool 'pt' exceeded time limits during shut down. The process id was '284'.//
  
 **Resolution:** **Resolution:**
 +
 +
  
 1.Manually started PT in the IIS manger within the application Pools. 1.Manually started PT in the IIS manger within the application Pools.
 +
 +
  
 2. open run command and and type services.msc. 2. open run command and and type services.msc.
 +
 +
  
 3. Double click IIS Admin Service. 3. Double click IIS Admin Service.
  
-{{:iis2.png?nolink&433}}+ 
 + 
 +{{::iis2.png?nolink&433|}} 
 + 
  
 4. Check to enable actions for stops with errors: 4. Check to enable actions for stops with errors:
 +
 +
  
 5. Chose Run Program: C:\Windows\system32\iisreset.exe 5. Chose Run Program: C:\Windows\system32\iisreset.exe
 +
 +
  
 6. for Command line perameters: type " /start" without quotations 6. for Command line perameters: type " /start" without quotations
 +
 +
  
 7. Retry Production terminal. 7. Retry Production terminal.
 +
 +
  
 =====   ===== =====   =====
 +
 +
  
 =====   ===== =====   =====
 +
 +
  
 =====   ===== =====   =====
 +
 +