Line 1: Line 1:
-======  ======+======   ======
  
 +==== Cause:  ====
  
- +Production Terminal not restarting service after reboot due to a Windows update.
-====**Cause:** Production Terminal not restarting service after reboot due to a Windows update.==== +
  
 **Event Viewer Log:** **Event Viewer Log:**
- 
- 
  
 //Administrative events reflected warning:A process serving application pool 'pt' exceeded time limits during shut down. The process id was '284'.// //Administrative events reflected warning:A process serving application pool 'pt' exceeded time limits during shut down. The process id was '284'.//
  
 **Resolution:** **Resolution:**
- 
- 
  
 1.Manually started PT in the IIS manger within the application Pools. 1.Manually started PT in the IIS manger within the application Pools.
- 
- 
  
 2. open run command and and type services.msc. 2. open run command and and type services.msc.
- 
- 
  
 3. Double click IIS Admin Service. 3. Double click IIS Admin Service.
  
- +{{:iis2.png?nolink&433}}
- +
-{{::iis2.png?nolink&433|}} +
- +
  
 4. Check to enable actions for stops with errors: 4. Check to enable actions for stops with errors:
- 
- 
  
 5. Chose Run Program: C:\Windows\system32\iisreset.exe 5. Chose Run Program: C:\Windows\system32\iisreset.exe
- 
- 
  
 6. for Command line perameters: type " /start" without quotations 6. for Command line perameters: type " /start" without quotations
- 
- 
  
 7. Retry Production terminal. 7. Retry Production terminal.
- 
- 
  
 =====   ===== =====   =====
- 
- 
  
 =====   ===== =====   =====
- 
- 
  
 =====   ===== =====   =====
- 
-