Differences

This shows you the differences between two versions of the page.

Link to this comparison view

Both sides previous revision Previous revision
503_error_production_terminal [2019/01/30 09:21]
127.0.0.1 external edit
503_error_production_terminal [2019/01/30 11:42] (current)
kcifreo
Line 1: Line 1:
-====== ​ ======+====== ​  ​======
  
 +==== Cause: ​ ====
  
- +Production Terminal not restarting service after reboot due to a Windows update.
-====**Cause:​** ​Production Terminal not restarting service after reboot due to a Windows update.==== +
  
 **Event Viewer Log:** **Event Viewer Log:**
- 
- 
  
 //​Administrative events reflected warning:A process serving application pool '​pt'​ exceeded time limits during shut down. The process id was '​284'​.//​ //​Administrative events reflected warning:A process serving application pool '​pt'​ exceeded time limits during shut down. The process id was '​284'​.//​
  
 **Resolution:​** **Resolution:​**
- 
- 
  
 1.Manually started PT in the IIS manger within the application Pools. 1.Manually started PT in the IIS manger within the application Pools.
- 
- 
  
 2. open run command and and type services.msc. 2. open run command and and type services.msc.
- 
- 
  
 3. Double click IIS Admin Service. 3. Double click IIS Admin Service.
  
- +{{:​iis2.png?​nolink&​433}}
- +
-{{::​iis2.png?​nolink&​433|}} +
- +
  
 4. Check to enable actions for stops with errors: 4. Check to enable actions for stops with errors:
- 
- 
  
 5. Chose Run Program: C:​\Windows\system32\iisreset.exe 5. Chose Run Program: C:​\Windows\system32\iisreset.exe
- 
- 
  
 6. for Command line perameters: type " /​start"​ without quotations 6. for Command line perameters: type " /​start"​ without quotations
- 
- 
  
 7. Retry Production terminal. 7. Retry Production terminal.
- 
- 
  
 =====   ===== =====   =====
- 
- 
  
 =====   ===== =====   =====
- 
- 
  
 =====   ===== =====   =====
- 
-